<h2> New standard for installation wires and cables </h2> <p> GOST 31947-2012 compared with GOST 6323-79 introduced the following new requirements: </p> <ol class = "vacancyOrder"> <li> Wires with aluminum conductors are excluded. Conducting conductors are made only from copper wire (tinned and not tinned). </Li> <li> Cables with a conductor core cross section of 0.75-50 mm² are included. The number of lived in the cables - 2,3,4,5. </Li> <li> The range of conductor cores has been extended: </li> <ul class = "vacancyTextList"> <li> for single-core wires from 0.5 to 400 mm²; </li> <li> two-, three-core wires from 0.75 to 4.0 mm². </li> </ul> <li> Conductive conductors for flexibility can be: </li> <ul class = "vacancyTextList"> <li> not requiring increased flexibility (1 class up to 10mm², 2 classes over 10mm²); </li> <li> increased flexibility (grade 5). </li> </ul> <li> The design of stranded wires and cables should be as follows: </li> <ul class = "vacancyTextList"> <li> flat - for wires; </li> <li> round - for cables. </li> </ul> <li> Main conductors, grounding conductors for wires and cables, and zero conductor cables must have <b> the same cross section </b>. Allowed in three-, four- and five-core cables with a nominal cross-section of the main conductors of 25mm2 and above, the grounding conductor of a smaller section in accordance with Table 3. </li> <p>  <b> Table 3 </b> <br> </p> <table class = "cableTable refTable overflowTable" cellpadding = "0" cellspacing = "0"> <thead> <tr> <th> Name of the vein </th> <th colspan = "3"> Nominal cross-section of the core, mm² </th> </tr> </thead> <tbody> <tr> <td> Main vein </td> <td> 25 </td> <td> 35 </td> <td> 50 </td> </tr> <tr> <td> Earth conductor </td> <td> sixteen </td> <td> sixteen </td> <td> 25 </td> </tr> </tbody> </table>  <br> <li> A color marking system has been introduced for the purpose of identifying them (the preferred color scheme is shown in Table 4): </li> <ul class = "vacancyTextList"> <li> Coloring should be solid. </Li> <li> It is not recommended to use <b> red and white </b> colors. </Li> </ul> <p>  <b> Table 4 </b> </p> <table class = "cableTable refTable overflowTable" cellpadding = "0" cellspacing = "0"> <thead> <tr> <th rowspan = "3"> The number lived in the cable, pcs. </th> <th colspan = "5"> Core insulation color </th> <th rowspan = "3"> Designated - <br> niya </th> </tr> <tr> <th style = "display: none;"> </th> <th colspan = "5"> Serial number of the core </th> </tr> <tr> <th style = "display: none;"> </th> <th> one </th> <th> 2 </th> <th> 3 </th> <th> four </th> <th> five </th> </tr> </thead> <tbody> <tr> <td rowspan = "2"> 3 </td> <td> Korich- <br> nevy </td> <td> The black </td> <td> Natural- <br> ny </td> <td>  <br> </td> <td>  <br> </td> <td>  <br> </td> </tr> <tr> <td style = "display: none;"> </td> <td> Korich- <br> new one </td> <td> Blue </td> <td> Green yellow </td> <td>  <br> </td> <td>  <br> </td> <td> N, PE </td> </tr> <tr> <td rowspan = "2"> four </td> <td> Korich <br> new one </td> <td> Black <br> </td> <td> Natural- <br> ny <br> </td> <td> Blue </td> <td>  <br> </td> <td> N </td> </tr> <tr> <th style = "display: none;"> </th> <td> Korich- <br> new one </td> <td> Black <br> </td> <td> Natural- <br> ny <br> </td> <td> Green yellow </td> <td>  <br> </td> <td> PE </td> </tr> <tr> <td rowspan = "2"> five </td> <td> Korich <br> new one </td> <td> Black <br> </td> <td> Natural- <br> ny <br> </td> <td> Blue </td> <td> Green-yellow <br> </td> <td> N, PE </td> </tr> <tr> <th style = "display: none;"> </th> <td> Korich- <br> new one </td> <td> Black <br> </td> <td> Natural- <br> ny <br> </td> <td> The black </td> <td> Blue </td> <td> N </td> </tr> </tbody> </table>  <br> <li> Compulsory presence of filling the outer gaps between the twisted insulated conductors, including in the form of an extruded inner sheath, to make the cables and wires almost round or flat. </li> <ul class = "vacancyTextList"> <li> The absence of a sheath in a single conductor is allowed. </li> <li> The coloring of the shell is not normalized. </li> </ul> <li> A requirement has been introduced for a minimum mass of one meter of a conductive core, in order to exclude the possibility of supplying cables with a reduced cross-section of conductive cores </li> <li> The permissible current loads for wires and cables are given. </li> <li> Fire safety requirements have been entered. Low-risk fire cables and cables were introduced that do not emit corrosive-active products and with low toxicity. </Li> </ol><h2> Cable product designation: </h2> <p> Cables and wires are divided into the following features: <br> </p> <ol class = "vacancyOrder"> <li> <b> by product type: </b> </li> <ul class = "vacancyTextList"> <li> installation wire (<b> Pu </b>); </li> <li> installation cable (<b> Ku </b>); </li> </ul> <li> <b> by flexibility: </b> </li> <ul class = "vacancyTextList"> <li> for installation and operation conditions that do not require increased flexibility (<b> without designation </b>); </li> <li> requiring increased flexibility (<b> G </b>), </li> </ul> <li> <b> by type of insulation material and sheath: </b> </li> <ul class = "vacancyTextList"> <li> polyvinyl chloride plastics, including low fire hazard and heat resistant (<b> B </b>); </li> <li> halogen free polymer compositions (<b> P </b>). </li> </ul> <li> <b> for performance in terms of fire safety indicators: </b> </li> <ul class = "vacancyTextList"> <li> non-flammable with single laying (<b> without designation </b>); </li> <li> non-flammable during group laying, with reduced smoke and gas emission - <b> ng (A, B, C, D) -LS </b> </li> <li> non-propagating combustion in group laying, with reduced smoke and gas emission, with low toxicity of combustion products - <b> ng (A, B, C, D) -LSLTx </b>; </li> <li> non-flammable during group laying and not emitting corrosive gaseous products during combustion and smoldering - <b> ng (A, B, C, D) -HF </b>; </li> <li> non-propagating combustion during group laying and not emitting corrosive gaseous products during combustion and smoldering, with low toxicity of combustion products - <b> ng (A, B, C, D) -HFLTx </b>. </li> </ul> </ol> <h2> Examples of legend: </h2> <p> Installation wire that does not require increased flexibility with PVC insulation with one core with a nominal cross section of 2.5 mm², without a sheath - wire <b> PuV 1 × 2.5 </b> <br>  <br> Installation cable requiring increased flexibility with PVC insulation and sheath, with reduced smoke and gas emission, does not propagate combustion in category A, with three main and zero conductors with a nominal cross section of 25 mm² and a ground conductor with a nominal cross section of 16 mm² - cable <b> КУВВнг (A) -LS 4 × 25 (N) + 1 × 16 (PE) </b> </p>  <br> <p>  <b> Table of new cable brand designations </b> </p> <table class = "cableTable refTable overflowTable" cellpadding = "0" cellspacing = "0"> <thead> <tr> <th colspan = "2"> Designation of wire and cable brands </th> </tr> <tr> <th> TU 3500-022-59680632–2011 </th> <th> GOST 6323-79 </th> </tr> </thead> <tbody> <tr> <td> Puv </td> <td> PW1 </td> </tr> <tr> <td> Pug </td> <td> PV2, PV3, PV4 </td> </tr> <tr> <td> Puvv </td> <td> PPV </td> </tr> <tr> <td> Pugvv </td> <td> - </td> </tr> <tr> <td> Kuvv </td> <td> - </td> </tr> <tr> <td> CuGVV </td> <td> - </td> </tr> <tr> <td> - </td> <td> Auto Recloser </td> </tr> <tr> <td> - </td> <td> APPV </td> </tr> <tr> <td> Puwng (A) -LS </td> <td> - </td> </tr> <tr> <td> Pugvng (A) -LS </td> <td> - </td> </tr> <tr> <td> PuVVng (A) -LS </td> <td> - </td> </tr> <tr> <td> Pugvvng (A) -LS </td> <td> - </td> </tr> <tr> <td> QuVWng (A) -LS </td> <td> - </td> </tr> <tr> <td> KuGVVng (A) -LS </td> <td> - </td> </tr> <tr> <td> PuPng (A) -HF </td> <td> - </td> </tr> <tr> <td> PuGPng (A) -HF </td> <td> - </td> </tr> <tr> <td> Puppng (A) -HF </td> <td> - </td> </tr> <tr> <td> PuGPPng (A) -HF </td> <td> - </td> </tr> <tr> <td> KuPPING (A) -HF </td> <td> - </td> </tr> <tr> <td> CAPP (A) -HF </td> <td> - </td> </tr> </tbody> </table>  <br> <p>  <b> <br>   </b> </p> <p>  <b> Predominant use of wires and cables </b> </p> <table class = "cableTable refTable overflowTable" cellpadding = "0" cellspacing = "0"> <thead> <tr> <th> Mark </th> <th> Predominant scope </th> </tr> </thead> <tbody> <tr> <td> Puv </td> <td> For laying electrical wiring in steel pipes, boxes, trays, etc., for mounting electrical circuits </td> </tr> <tr> <td> Pug </td> <td> The same for the installation of electrical circuits, where greater flexibility is required when laying and assembling </td> </tr> <tr> <td> Puvv </td> <td> For laying electrical wiring under plaster, in concrete, masonry, in hollows of building structures, and also openly on the surface of walls and ceilings and in other structures, for mounting electrical circuits </td> </tr> <tr> <td> Pugvv </td> <td> The same for the installation of electrical circuits, where greater flexibility is required when laying and assembling </td> </tr><tr> <td> Kuvv </td> <td> For laying in lighting networks, electrical wiring, installation and connection of household appliances, for laying electrical wiring under plaster, in concrete, masonry, in the voids of building structures, and also openly on the surface of walls and ceilings and in other structures, for mounting electrical circuits </td> </tr> <tr> <td> CuGVV </td> <td> The same for the installation of electrical circuits, which require increased flexibility during installation and installation </td> </tr> </tbody> </table>
Specifications
Quality
Modernisation and optimisation of production is carried out at the enterprise on a regular basis. Every stage of the finished product manufacturing process is automated and is under 100% strict control: from the selection of raw materials to shipment for the warehouse.
Optimal production time
Orders are put into production on the day of ordering as per the terms and conditions of the Contract.
Fair price
We manufacture products from high quality materials only after a strict inspection of their quality. We guarantee a fair price for high quality products.
Delivery/payment
Tomsk cable factory offers a flexible payment system for its customers and the timely delivery of products within Russia and for foreign countries.
Products certified
The quality of Tomskkabel products is confirmed by certificates of the Technical Regulations of the Customs Union, GAZPROMSERT, GOST R, Military Register, Maritime Register, certificates of compliance with the requirements of technical regulations On Fire Safety Requirements, and a license for the right to manufacture and the supply of products for the nuclear industry.
You have not found products or do not know the exact parameters and brand of cable?
Call +7 (3822) 49-80-09, and our managers will help to you find a suitable cable.
Characteristics, weights and structural dimensions, presented on the website, are for informational purposes only. 
Feel free to ask the managers any questions you might have.
Please wait..

Оставьте ваш e-mail и мы вышлем вам каталог

Некорректно заполнен адрес электронной почты

Спасибо! Ваша заявка отправлена.

Подписаться на новости



Некорректно заполнен адрес электронной почты

Что-то пошло не так. Попробуйте позже.

Подтвердите что Вы не робот!

Спасибо! Ваша подписка оформлена.